OXYGEN GENERATOR. PSA 5L.V1


Internal Reference: FABPSA.0052

OXYGEN GENERATOR. PSA 5L.V1

Oxygen generator with compressor, air treatment unit and filtration unit, with 5 lpm output at >90% oxygen purity. 230 V, 50 Hz, 700 W.

PSA high performance oxygen generation system. Manufactured with bi-column concentrator, compressor, flow meter, air treatment unit, filtration unit, PLC control and touch screen. Allows data logging and remote access. Manufactured with high quality components, ready for electrical connection and operation. 

Highly recommended
2 years extended warranty
 

Request a quote

Generador de Oxígeno

Product Details

What´s included

Compressed air unit Pre-filter + Compressor + Filtration unit + Air handling unit
Oxygen concentrator Activated alumina bi-column concentrator, 95% purity
Sensors Ampere Consumption, Compressed Air Pressure, Pressure, Temperature and Oxygen Flow, Door Opening.
Technical Valves Motorised Oxygen Outlet Valve, Oxygen Flow Meter with Manual Regulation
Control 4.3’ touch-screen PLC, with scheduler, alarm manager, maintenance and data logging.
Communication On Remote wired, Status relays (Initiated, Fault). Allows ModBus communication.
Salida Condensados OUT 8 mm diameter

Technical features

Packed size Consult
Gas connection OUT Tube 10 mm outer diameter
Power supply 230 V, 50 Hz
Electric Power 700 W
Air/Oxygen flow 5 l/min
Dimensions 400 x 300 x 910 (Width x Depth x Height)

Working Conditions

Room fittings The room should be well ventilated, away from sources of heat and excessive humidity.
Room temperature 5 - 35 ºC
Humidity <85%
Source gas Oxygen is generated by the equipment itself with its PSA unit.

Additional information

Made by ZonoSistem
Last revision 2024
Sold from 2024
Made in Spain

Functioning

When starting the ozone generator, it sends a start signal to the oxygen generator. The compressors turn on and suck the air from the surroundings. The compressed air is dryed and lead to the zeolite filled deposits where the nitrogen is removed leaving oxygen a high concentration. This oxygen is then lead to the auxiliary compressor which impulses the oxygen to the outlet to be lead to the ozone generator.

Documentation Included

  • Safety manual.

  • User manual, installation and commissioning.

  • Maintenance manual.

  • Declaration of conformity.

  • Certificate of guarantee.

  • Compliance with the biocidal regulation.

  • Results of the Quality Test in the factory.

Technology

This oxygen generator uses zeolite coulmns to produce high cocentration oxygen.