HIDRO V 84.90 Recirculation plant to dilute ozone
HIDRO V type recirculation plant, designed to dilute ozone in a water tank. 220V, 50HZ, 750W. with 6.6m3/h pump, 3/4" venturi, safety valve, sensors and electrical panel.
Achieve a high dilution of ozone in the water tank with the HIDRO V ozone recirculation and injection system, made up of a venturi and an accelerator pump. Mounted on stainless steel bench. Includes regulation bypass, pressure gauges, electrical panel, motorized safety valve, safety anti-return, and user manual. Ozone generator not included.
Manufacturing in 7 days
Recirculation plant to dilute ozone
Data sheet
What is it used for?
This system is used to inject ozone into a tank or reservoir, through water recirculation and venturi suction. The Hydro takes water from the tank, injects ozone into it and returns it to the tank. It is also used to recirculate directly over a pressurized pipe.
Product Details
Room fittings | It is recommended that the room have a drainage box, and an ozone leak sensor, a sign with safety warnings. |
Pump | 6.6m3/h stainless steel pump included |
Venturi | 2" included, built in PVDF |
Electricity and electronic | Includes electrical protection panel with pump circuit breaker and terminals for connection of peripherals. |
Sensors | Visual pressure gauge, minimum pressure switch, maximum pressure switch |
Technical Valves | Includes motorized valve, 316L stainless steel check valve, manual regulation bypass |
Bench | Constructed of 304 Stainless Steel |
Recirculation Flow | 6,6m3/h a 1,5 bar |
Maximum suction flow | 12 lpm |
Hydraulic connection | IN/OUT = 3/4" |
hydraulic pipes | PVC 32 mm Glue |
Presión de diseño | 0,5 Bar |
Gas connection | Tube outer diameter 8 mm |
Electric Power | 1,5kW |
Power supply | 230V, 50-60 Hz |
Dimensions | 590 x 600 x 1500 mm (Width x Depth x Height) |
Packed size | 880 x 770 x 1850 mm (Width x Depth x Height) |
Weight | 81kg | Packed 115 Kg |
Humidity | <85% |
Room temperature | 5-40ºC |
Fluid temperature | 5-30ºC |
Fluid freatures | Ǿ Solids < 1mm; Suspended solids (SS)<150mg/l; Density = 1 g/cm3 ± 5% |
Hydraulic Working Pressure | Between 0 and 6.5 bar |
Made by | ZonoSistem |
Made in | Spain |
Sold from | 2014 |
Last revision | 2021 |
Certificates | CE |
Warranty | 2 years extendable indefinitely, with maintenance contract |